DCDB boxes protect the DC side of your system between panels and inverter, while ACDB boxes protect the AC side between the inverter and your electrical distribution board. Select protection equipment using the system design and exact circuit ratings.
Solar ACDB Box

ACDB for 1 KW to 5 KW Systems
AC-side surge and protection box suitable for residential rooftop systems.
Solar DCDB Box

DCDB for 1 KW to 3 KW Systems
DC-side protection box suitable for smaller residential systems.

DCDB for 5 KW & Above Systems
DC-side protection box suitable for larger residential and commercial systems.
Enquire About ACDB / DCDB Boxes
Specify AC and DC protection separately
ACDB and DCDB assemblies must match the design voltage, current, strings and inverter. A system capacity in kW is not enough to select every protection device or enclosure.
Share the single-line diagram and installation conditions. Request component ratings and testing records; installation and live-equipment inspection belong with qualified electrical personnel.
Begin with the single-line diagram
Specify the inverter, PV strings, maximum circuit values and connection arrangement. DC and AC switching devices have different application requirements; never substitute an AC-rated item on a DC circuit solely because its current label appears similar.
Whether functions sit in a separate box or integrated equipment depends on the design and the selected products. A generic kW package is not enough to establish every component rating.
Coordinate enclosure, surge protection and earthing
Match the enclosure to the installation environment and follow the component manufacturers’ requirements. Heat, moisture, cable entries and access affect the final assembly.
Protection and earthing are complementary parts of the system; a distribution box does not replace a designed earthing arrangement. A qualified electrical designer should coordinate the complete circuit.
What to obtain with a supplied or installed box
Request the component schedule, ratings and relevant documentation for the exact assembly. Confirm labels, testing records and the service procedure as part of handover.
State whether delivery, installation, cabling and commissioning are included. Only qualified personnel should open, isolate or inspect live equipment.
Clear answers
Frequently asked questions
What is an ACDB in a solar installation?
An AC Distribution Box contains the specified distribution and protection components on the AC side of the inverter.
What is a DCDB in a solar installation?
A DC Distribution Box contains specified components on the photovoltaic DC side. Its design depends on the array and inverter arrangement.
Can an AC protection device be used in a DC circuit?
Do not substitute it unless the manufacturer explicitly rates it for the DC application. AC and DC switching requirements differ.
Does every installation need identical distribution boxes?
No. String count, voltage, current, inverter features and site requirements determine the protection design.
How are surge protection devices selected?
Selection depends on the circuit, voltage and site protection design. A qualified designer should coordinate devices with the rest of the system.
Does a DCDB replace earthing?
No. Protection equipment and earthing have different functions and must be coordinated within the complete safety design.
Can I choose a distribution box only by solar kW rating?
No. Circuit voltage, current, strings, fault considerations and device ratings also matter.
Are enclosures suitable for all outdoor locations?
Suitability depends on the enclosure rating, exposure, heat and installation instructions. Confirm the intended mounting location.
Who should install ACDB and DCDB equipment?
Qualified electrical personnel should install and test the equipment according to the approved design and manufacturer instructions.
What should I include in a protection-box enquiry?
Share the single-line diagram, inverter model, string details, voltage and current ratings, location and required quantity.
Can I inspect a live distribution box myself?
Do not open or work on live equipment. Arrange inspection and safe isolation by qualified electrical personnel.
What should be checked at handover?
Obtain equipment ratings, circuit labels, relevant test records, protection details and instructions for safe operation and maintenance.